Elettronica Pagani HC IR 1.6W Laser
A very effective laser device, capable of delivering high energy density. Thanks to its most innovative solid state laser source of 808nm, HC-IRED is capable of treating all the acute and chronic pathologies without any special collateral effects and contraindications, with effectiveness, care and safety.
The new technologic solutions of HC I-RED, make 808nm infrared laser beam useful for a large spectrum of pathologies of muscles, tendons, bones and skin conditions.
It is possible to perform treatments manually for treating trigger and/or tender points by making very small movements all over the affected area.
HC I-RED may deliver high energy density to the deepest tissues thanks to the special features of the source itself as well as the electronic system that allows it to keep power constantly throughout the whole application time.
Continuous and pulsed modes
HC I-RED is one of the most traditional high energy laser device, provided with a new solid state laser source working with a peak of 1.600 mW, both in continuous and in pulsed emission modes, for provoking both thermal and non-thermal actions over the different cellular layers, depending on the status of the pathology and on the aim of each treatment.
All the energy you need
The operator may select a wide range of functions: starting from the opportunity to set frequency from 10 to 20.000 Hz, depending on the emission modality he would prefer.
Also, from the energy point of view, HC I-RED, thanks to the high power laser source is capable to generate high energy density up to 1450 J/cm2 while 30minutes application time
has been set the software of HC I-RED and could be used separately or combined into the same applications.
Trigger points and manual scanning
From the clinical experience along with the technical knowledge, HC I-RED was provided with a wide range of useful functions for treating trigger (or tender) points automatically and also painful and inflamed areas by a small manual movement over the areas to be treated. Each modality is suggested from the software of HC IR and could be used separately or combined into the same applications.
Technical features
Laser source type: IR 808 nm
Power supply: 115 – 230, 50/60 Hz, +/- 10%
Frequency: from 1 to 300 Hz
Continuous, pulsed, trigger points: As standard
Peak power: 1.600 mw (1,6 W)
Effective power: up to 1.200 mw (1,2 W)
Duty cycle 10% – 100%
Automatic calculation of energy density and application time
Pre-set protocols with pictures
Free memories for storing customized protocols
Pointer Encoder: Touch-screen
Coloured touch-screen 480×800 pixels
Protective goggles: One, as standard
On inquiry:
Wheeled frame device with boxes
Second protective goggles
Roland trolley
HC trolley
Carrying case.